| Installation Condition | Flush | Non-Flush | |
| Sensing Distance Sn | 10 mm | 15 mm | |
| Product Code | NPN NO | CPS30DC-TNC-F10NNO | CPS30DC-TNC-N15NNO |
| NPN NC | CPS30DC-TNC-F10NNC | CPS30DC-TNC-N15NNC | |
| NPN NO+NC | CPS30DC-TNC-F10NNB | CPS30DC-TNC-N15NNB | |
| PNP NO | CPS30DC-TNC-F10PNO | CPS30DC-TNC-N15PNO | |
| PNP NC | CPS30DC-TNC-F10PNC | CPS30DC-TNC-N15PNC | |
| PNP NO+NC | CPS30DC-TNC-F10PNB | CPS30DC-TNC-N15PNB | |
| Housing Size (mm) | M30 × 1.5 × 62 | M30 × 1.5 × 74 | |
| Switching Frequency | 50 Hz | ||
| Supply Voltage | 10…30 V DC | ||
| Voltage Drop Static | ≤ 2.5 V | ||
| Temperature Drift | ≤ ±10 % | ||
| Load Current | ≤ 200 mA | ||
| No-Load Current | ≤ 15 mA | ||
| Hysteresis | 3…20 % | ||
| Repeat Accuracy | ≤ 3 % | ||
| Output Indicator | LED, Yellow | ||
| Protection Circuit | Reverse Polarity, Overloaded, Short-circuit and Surge Protection | ||
| Ambient Temperature | -25…+70 ℃ | ||
| Ambient Moisture | 35…95 % | ||
| Enclosure Type (IEC 60529) | IP67 | ||
| Housing Material | Nickel-Copper Alloy | ||
| Connection | PVC Cable 2m | ||
| Approvals / Conformity | CE | ||